상세정보
Image View
 
 
 
 
광전자분광장치용 샘플스테이지
제조사/원산지
R-DEC, JAPAN
상품가
0 원
판매가
견적가
주문수량
+ -
적립금
0 점
상품상세정보


i-Gonio 물리학 실험에 사용되는 광전자분광장치(光電子分光装置)

Sample  stage(샘플스테이지) 사용되고 있으며, 광전자분광(光電子分光) 중에서도 물질의

밴드구조를 직접 측정하는 방법인 각도분해광전자분광(角度分解光電子分光) 측정 목적에

특히 사용되고 있습니다.

일본 R-DEC사의 i-gonio 초고진공상태에서 초저온으로 냉각시킨 샘플의 각도를 움직이면서

실험하는것이 가능한 度分解型光電子分光에 최적인 극저온시료 냉각스테이지 입니다.

---------------------------------------------------------------------------------------------------------


R-DEC, in collaboration with AIST (National Institute of Advanced Industrial Science and Technology), has developed a new UHV Compatible High-Precision Goniohead with 6-axis stage and sample cooling function for simultaneous pursuit of sample cooling at cryogenic temperature (below 10K) & 6-axis manipulation (XYZ, flip, and in-plane rotation) of the sample under UHV conditions.

Common Specifications
Cooling system:
Heater:
Magnetism:
Bias application:
Sample transfer:
Liquid Helium flow
Built-in low temperature controller
Non-magnetic
Sapphire floating (option)
Standard with all i-GONIO models

 

 

 

Real Shaft Single or Double Flip Stages Type

· Greatest cooling capability among all flip stage type

  cryoheads

· Fixed/ Flip combination type available
 

Specifications
Stage:
Cooling temperature:

Range of flip:
Flip resolution:
Radiation shield:
flip (upper stage is fixed in the case of double-flip stage)
10K (flip stage)
7K (fixed stage)
-5 degrees to 60 degrees
0.05 degrees
open and close type


Real Shaft In-plane Rotation Type  
· Greatest cooling and angle resolution capability among in-plane rotation cryoheads 
 
Specifications
Stage:

Cooling temperature:
In-plane resolution:
Radiation shield:
in-plane rotation
[Max. +/-90 degrees]
9K
0.1 degrees
fixed type

0-axis Type
· Compatible with various forms of sample holders
· Compact design of φ58mm inner diameter
· Compatible with multiple sample holders

Specifications
Stage:
Cooling temperature:
Radiation shield:
fixed double-stage (stage selectable)
7K (double stages / floating available)
open and close type


Virtual Shaft Single-Axis Type
· Symmetry design makes it possible to transfer samples in all directions 
  and to aim beams on targets at all angles.

Specifications
Stage:
Cooling temperature:
Radiation shield:
Flip resolution:
flip
12K
-5 degrees to 60 degrees
0.05 degrees


Virtual Shaft Double-Axis Type 
· Compatible with six-axis manipulator by using X/Y/Z/θ stage

Specifications
Stage:

Cooling temperature:
Radiation shield:
Flip resolution:
In-plane resolution:
flip / in-plane rotation
[Max. +/- 90 degrees]
12K
-5 degrees to 60 degrees
0.05 degrees
0.2 degrees

 

  
배송/반품/교환
 